本文へスキップ
We are the manufactuer of medical simulation and training models, based on our own research and technology.

TEL. +81-3-6905-6571

2-64-5, Itabashi, Itabashi-ku, Tokyo 173-0004

PRODUCT

Pregnancy external examination model

Summary


The installation into a SP (simulated patient) of a fetal model that corresponds to a particular number of weeks of pregnancy creates a realistic simulation for health examinations of pregnant women. This is helpful for learning midwifery diagnosis techniques, and communication with a simulated pregnant woman provides good educational benefits. It realistically reproduces the sizes of a fetus and a placenta, fetal presentation, position, and palpations, meaning it can be used for childbirth preparation education.


Development cooperation


The Japanese Red Cross School of Midwifery





Features


It is possible to use this to practice midwifery techniques necessary for midwifery diagnosis.
The installation into a SP of a fetal model that corresponds to a particular number of weeks (20, 32, and 40 weeks) of pregnancy allows the creation of a simulated pregnant woman.
It is possible to perform palpation of the fetal dorsum, fetal head, acromion (brachi-cranial bone), gluteal region, and greater trochanter, which can be used as guides for abdominal palpation.
Simulated amniotic fluid allows the creation of a realistic sensation during abdominal palpation.
The use of simplified breasts attached to an apron enables exercises in breast care.
It is possible to connect commercial earphones to the fetal abdomen through the lower part of the apron to practice auscultation of fetal cardiac sounds.



    Section for guiding palpation    Simulated amniotic fluid
           


Configuration


MC-002 Full set version
Apron MC-002AP 
Fetus model with placenta Type A (20 weeks) MC-002F5
Fetus model with placenta Type B (32 weeks) MC-002F8 
Fetus model with placenta Type C (40 weeks) MC-002F10
Simulated amniotic fluid Type A (for the 20th weeks) MC-002AF5
Simulated amniotic fluid Type B (for the 32nd and 40th weeks ) MC-002AF10
Additional amniotic fluid MC-002AD


MC-002W40 40 weeks version
Apron  MC-002AP 
Fetus model with placenta Type C (40 weeks) MC-002F10 
Simulated amniotic fluid Type B (for the 32nd and 40th weeks ) MC-002AF10 
Additional amniotic fluid MC-002AD 

Each of the above spare parts are available.



Specifications


Apron
Material: 100% cotton for the quilting section, 100% polyester for the chest and abdomen, and urethane foam for the breasts
Dimensions: Height of abdominal region (commonly used for 32nd and 40th weeks): 30cm
Weight: Approx. 640g (sewn section only)
Simulated amniotic fluid
Material: Silicone gel
Dimensions: (A) approx. 24x20cm and (B) approx. 31x28cm
Weight: (A) approx. 480g and (B) approx. 1760g
Fetus
Material: 100% cotton for the placenta and sewn sections
Contents: Urethane foam and silicone rubber for the head, arms, and legs
Dimensions: (A) approx. 33cm, (B) approx. 45cm and (C) approx. 50cm
Weight: (A) approx. 460g, (B) approx. 1150g and (C) approx. 1520g

The weight of the complete fetus installation for the 40th week is approx. 3.9kg


In order to continually improve the products, the specifications may change without prior notice. Made in Japan


Note


The uterine fundus and abdominal circumference corresponding to the number of weeks of pregnancy can deviate depending on the body shape of the person wearing this product.

Pregnancy external examination model movie



Fetus model with placenta



    40 weeks      32 weeks   20 weeks



Arrangement of a fetal model with placenta (40th and 32 weeks)


Remove the abdominal cover of the apron to insert a fetus.

It can be set freely with cephalic and pelvic presentation.
It is possible to change the feel during palpation by changing the position of the placenta, the position of the additional amniotic fluid, the position of the limbs (above, below of the additional amniotic fluid, etc.).

Place the simulated amniotic fluid over the fetus.

The simulated amniotic fluid has "↑" printing. Simulated amniotic fluid is thick on the arrow side. When setting the 32 week fetus, put the arrow on the chest side, and when setting the 40 week fetus, cover the side of the pubic side with the arrow side.

Install the abdominal cover.

Attach the abdominal cover so as not to damage simulated amniotic fluid with the zipper.

Close the zipper.

Abdominal cover is a consumable item. If pilling etc. stand out, please exchange it with a new one.


Arrangement for the 20th week fetal model


Insert the 20 week fetus from the back of the apron.

Insert the 20 weeks fetus and simulated amniotic fluid through the poket at the back of the apron。(Though picture is Velcro、zipper is adopted on the product.)

The condition in which the 20 week fetus is contained.

The place where 32 and 40 weeks fetus placed is turned to be abdominal wall during 20 weeks fetus setting.



Connection earphone






Changing the amount of simulated amniotic fluid


Changing the amount of simulated amniotic fluid

It is possible to change the amount of amniotic fluid by combining simulated amniotic fluids A and B and the fluid for replenishment.

Setting the arms and legs of the fetus in the simulated amniotic fluid for replenishment allows the use to change the method of touching the abdomen.




Fetal heart sounds


Fetal heart sounds can be downloaded by registering from the dedicated URL (password is required). Please copy the heart sounds to a music player for use.
The heart sounds of a fetus range from 80bpm to 160bpm and are recorded in units of 10bpm in each track. The length of each track is 3 min.

Track 1:80bpm  Track 2:90bpm  Track 3:100bpm 
Track 4:110bpm  Track 5:120bpm  Track 6:130bpm 
Track 7:140bpm  Track 8:150bpm  Track 9:160bpm 
*No earphones or music player are supplied with this product. Please prepare separately.




ナビゲーション

バナースペース

MEDICAL CRAFT AND PROSTHETICS CO.,LTD.

2-64-5 Itabashi, Itabashi-ku, Tokyo 173-0004

TEL +81-3-6905-6571
FAX +81-3-6905-6572